Cylinder Specifications/Storage and Use

High-Pressure Aluminum Refillable Lecture Bottles

[table "12" not found /]

* Refillable cylinders are the property of Scott Medical Products. Customers may not load or refill any cylinder furnished by Scott Medical Products as it is prohibited by Federal Regulations.


High-Pressure Returnable Cylinders

[table "14" not found /]

* Refillable cylinders are the property of Scott Medical Products. Customers may not load or refill any cylinder furnished by Scott Medical Products as it is prohibited by Federal Regulations.


Low-Pressure Returnable Cylinders

[table "15" not found /]

Disposable High-Pressure Cylinders

[table "17" not found /]

Disposable Low-Pressure Cylinders

[table "19" not found /]

CGA Cylinder Valve Outlets and Connections

Connection 110

connection 110 5/16 - 32 RH INT. with Gasket

5/16″ – 32 RH INT. with Gasket

Connection 160

connection 110 5/16 - 32 RH INT. with Gasket

1/8″ – 27 NGT RH INT.

Connection 165

connection 110 5/16 - 32 RH INT. with Gasket

0.4375″ – 20 UNF 2A RH EXT.

Connection 170

connection 110 5/16 - 32 RH INT. with Gasket

5/16″ – 32 RH INT., with Gasket

Connection 180

connection 110 5/16 - 32 RH INT. with Gasket

0.625″ – 18 UNF 2A RH EXT. with Gasket (washer or O-ring may be used)

Connection 296

connection 110 5/16 - 32 RH INT. with Gasket

0.803″ – 14 RH INT.

Connection 320

connection 110 5/16 - 32 RH INT. with Gasket

0.825″ – 14 RH EXT. with Gasket

Connection 326

connection 110 5/16 - 32 RH INT. with Gasket

0.825″ – 14 RH EXT.

Connection 330

connection 110 5/16 - 32 RH INT. with Gasket

0.825″ – 14 LH EXT. with Gasket

Connection 510

connection 110 5/16 - 32 RH INT. with Gasket

0.885″ – 14 LH INT.

Connection 350

connection 110 5/16 - 32 RH INT. with Gasket

0.903″ – 14 RH EXT.

Connection 580

connection 110 5/16 - 32 RH INT. with Gasket

0.965″ – 14 RH INT.

Connection 590

connection 110 5/16 - 32 RH INT. with Gasket

0.965″ – 14 LH INT.

Connection 600

connection 110 5/16 - 32 RH INT. with Gasket

1.000″ – 20 UNEF RH EXT. with Gasket

Connection 660

connection 110 5/16 - 32 RH INT. with Gasket

1.030″ – 14 RH EXT. with Gasket


Medical Gas Cylinder Valves for Pin-Indexed Connections

Connection 870

Connection 870 - Scott Medical Products

Connection 880

Connection 880 - Scott Medical Products

Connection 890

Connection 890 - Scott Medical Products

Connection 910

Connection 910 - Scott Medical Products

Connection 930

Connection 930 - Scott Medical Products

Connection 940

Connection 940 - Scott Medical Products

Connection 950

Connection 950 - Scott Medical Products

Connection 960

Connection 960 - Scott Medical Products

Connection 965

Connection 965 - Scott Medical Products

Connection 973

Connection 973 - Scott Medical Products

Connection 977

Connection 977 - Scott Medical Products


Cylinder Valve Outlets and Connections
Scott supplies specialty gases in cylinders with valves having the standard CGA, DIN, and BS outlet connections. In some cases, alternate CGA connections may be used and, upon a customer’s request, will be supplied instead of the standards shown below.

[table "20" not found /]